Browse IS/STAG - Portál ZČU

Skip to page content
Website ZČU
Portal title page ZČU
Anonymous user Login Česky
HelpDesk - user support contact
Browse IS/STAG
Login Česky
HelpDesk - user support contact
  • My info
  • Study
My portal
Welcome
Webmail JIS
JISSouhlas koloběžky
Browse IS/STAG Applicant
Information for applicantsElectronic applicationECTS arrivalsCourse catalog
Graduate
Getting startedAlumni ClubAbsolvent - website
Courseware
CoursewareCourses by Faculties

1st level navigation

  • My info
  • Study

2nd level navigation

  • Browse IS/STAG
  • Applicant
  • Graduate
  • Courseware
User disconnected from the portal due to long time of inactivity.
Please, click this link to log back in
(sessions are disconnected after 240 minutes of inactivity. Note that mobile devices may get disconnected even sooner).

Browse IS/STAG (S025)

Help

Main menu for Browse IS/STAG

  • Programmes and specializations.
  • Courses
  • Departments
  • Lecturers
  • Students
  • Examination dates
  • Timetable events
  • Theses, selected item
  • Pre-regist. study groups
  • Rooms
  • Rooms – all year
  • Free rooms – Semester
  • Free rooms – Year
  • Capstone project
  • Times overlap
  •  
  • Title page
  • Calendar
  • Help

Search for a Thesis

Print/export:  Data export to PDF format - which you can print easily... Bookmark this link in your browser so that you may quickly load this IS/STAG page in the future.
Not logged-in user will see only submitted theses.
Only logged-in user will see student personal numbers.

Dates found, count: 1

Search result paging

Found 1 records Print Export to xls List URL
  Surname Name Title Thesis status   Supervisors Reviewers Type of thesis Date of def. Title
Student Type of thesis - - - - - - - - - -
Item shown in detail HOLÍK Includes the selected person into the timetable overlap calculation. Michael Precise position sensitive spectroscopy of energetic ions with adapted pixel device Precise position sensitive spectroscopy of energetic ions with adapted pixel device Thesis finished and defended successfully (DUO).   Georgiev Vjačeslav Kos Šimon, Pospíšil Stanislav, Štekl Ivan Doctoral thesis 1475791200000 07.10.2016 Precise position sensitive spectroscopy of energetic ions with adapted pixel device Thesis finished and defended successfully (DUO).
Michael HOLÍK Doctoral thesis 0XX 0XX 0XX 0XX 0XX 0XX 0XX 0XX 0XX 0XX

Thesis info Přesná polohově citlivá spektroskopie energetických iontů adaptací pixelového detektoru

  • Basic data
The document you are accessing is protected by copyright law. Unauthorised use may lead to criminal sanctions.
Name HOLÍK Michael Includes the selected person into the timetable overlap calculation.
Acad. Yr. 2014/2015
Assigning department KAE
Date of defence Oct 7, 2016
Type of thesis Doctoral thesis
Thesis status Thesis finished and defended successfully (DUO). Thesis finished and defended successfully (DUO).
Completeness of mandatory entries - The following mandatory fields are not filled in for this Thesis.: Title in English
Main topic Detekce a spektroskopie iontů pomocí pixelových detektorů
Main topic in English Precise position sensitive spectroscopy of energetic ions with adapted pixel device
Title according to student Přesná polohově citlivá spektroskopie energetických iontů adaptací pixelového detektoru
English title as given by the student -
Parallel name -
Subtitle -
Supervisor Georgiev Vjačeslav, doc. Dr. Ing.
Reviewer Kos Šimon, doc. Mgr. Ph.D., Pospíšil Stanislav, Ing. DrSc., Štekl Ivan, doc. Ing. CSc.
Consultant outside of the university Jakůbek Jan, Ing. Ph.D.
Annotation Hybridní pixelový detektor Timepix prokázal, že je velmi užitečným nástrojem v oblasti detekce ionizujícího záření a zobrazovaní. Vykazuje výjimečné schopnosti dovolující přesné měření energie částic, včetně směru jejich dopadu. Tyto schopnosti jsou dány vlastnostmi jako je velmi jemné prostorové rozlišení, či vysoké energetické rozlišeni dovolující registrovat kvantum energie od jednotlivých interagujících částic (fotonů). Spektroskopické schopnosti detektoru mohou být dále umocněny při zpracování analogového signálu ze společné elektrody pixelové matice detektoru. Tato práce se zabývá analýzou, zpracováním a využitím signálu ze společné elektrody pixelového detektoru. Výsledky získané předchozí studií jsou využitý k návrhu precizní jaderné instrumentace, která vyniká oproti ostatním již existujícím řešením díky svým vlastnostem (schopnost souběžné akvizice matic pixelového detektoru v kombinaci se záznamem signálu ze společné elektrody, vysoké spektroskopické rozlišení, vzájemná synchronizace, spouštění kombinovaného měření na základě velikosti energie interagující částice, atd.). Výsledky výzkumu a vývoje otevírají prostor pro nové využití detektoru Timepix na poli sledování těžkých nabitých iontů.
Annotation in English The hybrid semiconductor pixel detector Timepix has proven to be a powerful tool in radiation detection and radiation imaging. Energy loss and directional sensitivity as well as particle type resolving power are possible by high resolution particle tracking and per-pixel energy and quantum-counting capability. The spectrometric resolving power of the detector can be significantly enhanced by analyzing the analog signal of the detector common sensor electrode (also called the back side pulse). The thesis deals with the study of the backs side pulse signal analysis, processing and its exploitation. The results of the study are used in the subsequent development of the precise instrumentation with enhanced parameters (e.g. simultaneous acquisition of the back side pulse waveforms as well as pixelated matrices of the Timepix detector, high spectroscopic resolution, well-done synchronization, self-trigger capability on base of particle energy, etc.) in comparison to previously available solutions. The results of the research and development open a new application of the Timepix detector for further study of energetic ions
Keywords VHDL, FPGA, Experimentální fyzika, Alfa spektroskopie, Těžký nabitý iont, Radiace, Jaderná instrumentace, Timepix, Medipix, Pixelový detektor, Čtecí rozhraní, Zpracování dat, Zpracování signálů, Detektor, Kalibrace
Keywords in English VHDL, FPGA, Experimental physics, Alpha spectroscopy, Heavy charged ion, Energetic ion, Radiation, Nuclear instrumentation, Timepix, Medipix, Pixel detector, Read-out interface, Data processing, Signal processing, Detector, Calibration
Length of the covering note 140 s (266 445 znaků)
Language AN
Annotation
Hybridní pixelový detektor Timepix prokázal, že je velmi užitečným nástrojem v oblasti detekce ionizujícího záření a zobrazovaní. Vykazuje výjimečné schopnosti dovolující přesné měření energie částic, včetně směru jejich dopadu. Tyto schopnosti jsou dány vlastnostmi jako je velmi jemné prostorové rozlišení, či vysoké energetické rozlišeni dovolující registrovat kvantum energie od jednotlivých interagujících částic (fotonů). Spektroskopické schopnosti detektoru mohou být dále umocněny při zpracování analogového signálu ze společné elektrody pixelové matice detektoru. Tato práce se zabývá analýzou, zpracováním a využitím signálu ze společné elektrody pixelového detektoru. Výsledky získané předchozí studií jsou využitý k návrhu precizní jaderné instrumentace, která vyniká oproti ostatním již existujícím řešením díky svým vlastnostem (schopnost souběžné akvizice matic pixelového detektoru v kombinaci se záznamem signálu ze společné elektrody, vysoké spektroskopické rozlišení, vzájemná synchronizace, spouštění kombinovaného měření na základě velikosti energie interagující částice, atd.). Výsledky výzkumu a vývoje otevírají prostor pro nové využití detektoru Timepix na poli sledování těžkých nabitých iontů.
Annotation in English
The hybrid semiconductor pixel detector Timepix has proven to be a powerful tool in radiation detection and radiation imaging. Energy loss and directional sensitivity as well as particle type resolving power are possible by high resolution particle tracking and per-pixel energy and quantum-counting capability. The spectrometric resolving power of the detector can be significantly enhanced by analyzing the analog signal of the detector common sensor electrode (also called the back side pulse). The thesis deals with the study of the backs side pulse signal analysis, processing and its exploitation. The results of the study are used in the subsequent development of the precise instrumentation with enhanced parameters (e.g. simultaneous acquisition of the back side pulse waveforms as well as pixelated matrices of the Timepix detector, high spectroscopic resolution, well-done synchronization, self-trigger capability on base of particle energy, etc.) in comparison to previously available solutions. The results of the research and development open a new application of the Timepix detector for further study of energetic ions
Keywords
VHDL, FPGA, Experimentální fyzika, Alfa spektroskopie, Těžký nabitý iont, Radiace, Jaderná instrumentace, Timepix, Medipix, Pixelový detektor, Čtecí rozhraní, Zpracování dat, Zpracování signálů, Detektor, Kalibrace
Keywords in English
VHDL, FPGA, Experimental physics, Alpha spectroscopy, Heavy charged ion, Energetic ion, Radiation, Nuclear instrumentation, Timepix, Medipix, Pixel detector, Read-out interface, Data processing, Signal processing, Detector, Calibration
Research Plan -
Research Plan
-
Recommended resources -
Recommended resources
-
Týká se praxe No
Enclosed appendices -
Appendices bound in thesis illustrations, graphs, schemes, tables
Taken from the library Yes
Full text of the thesis
Thesis defence evaluation Passed
Appendices
Reviewer's report
Supervisor's report
Defence procedure record -
Defence procedure record file